[/vc_column_text][/vc_column_inner][/vc_row_inner][/vc_column][/vc_row][vc_row][vc_column][vc_custom_heading text=”FEATURES” font_container=”tag:h1|font_size:45|text_align:center|color:%23dd3333″ google_fonts=”font_family:Coda%3Aregular%2C800|font_style:400%20regular%3A400%3Anormal”][vc_column_text]
Reliable And Durable
Platypus Power’s simple design and use of the highest quality materials means long life and low maintenance.[/vc_column_text][vc_column_text]
Cooking
This model uniquely incorporates a stove element which harnesses any excess power for cooking and heating water. This cooking element makes use of the power which is normally wasted when excess power is dumped during regulation via an air element.[/vc_column_text][vc_column_text]
Adaptable
The Platypus Power unit is capable of high flows through a single nozzle. The single nozzle is easily changeable to suit seasonal flows, maintaining maximum output. All platypus units are compact with no bulky water manifold [/vc_column_text][vc_column_text]
Low Maintenance
The M1/125 uses larger bearings that are easy to source. The generators are very robust. Solid cast bars replace the rotor winding and enable the rotor to withstand considerable overspeed. In addition they are totally enclosed, ensuring good protection against dirt and water. They are designed for continuous operations under industrial conditions. Runaway speed is hydraulically limited. The turbine casing is made of corrosion resistant cast aluminium and the runner is stainless steel.
This all amounts to reliability and uninterrupted power supply[/vc_column_text][vc_column_text]
Mounting
An aluminium casing “skirt” extends below floor level, which seals water out of the turbine shed. It does not require bolting down, allowing easy access to the nozzle for cleaning. It is quick to install and the design baffles noise.[/vc_column_text][vc_column_text]
Connection
The M1/125 water inlet is via a standard table D 2 inch flange. It is a quick and easy connection with no nozzle aiming required. Price- These units are very competitively priced to compete with the portable generator market. Just e-mail for up to date pricing. Runner- Saving the best for last, the innovative hybrid Platypus impulse runner is 316 stainless steel to resist abrasion and corrosion. It is highly efficient over a wide range of pressures. Filtering to 3 mm is required. Platypus Power micro hydro units offer simplicity, quality, lasting value and performance. [/vc_column_text][vc_column_text]
EASY TO USE RELIABLE CONTROLS
Sophisticated but simple electronic controls ensure years of reliable electricity.
The unique Platypus Power Advanced Regulator protects your turbine – controlling the speed of the generator to keep the voltage stable. The turbine pricing includes the electronic control unit and dump element to keep the generator constantly at full load.
The regulator automatically diverts and dissipates unused energy through the stove element. Automatic shut down through the control board protects connected electrical equipment and the generator from over-voltage.
It is essential for your safety and the correct operation of these machines that they are installed in accordance with the relevant provisions of AS 3000 and AS 3010 and/or other appropriate standards in the country of installation.[/vc_column_text][/vc_column][/vc_row][vc_row][vc_column][ultimate_exp_section title=”SPECIFICATIONS” new_title=”Specifications” text_color=”#ffffff” background_color=”#0078ae” text_hovercolor=”#ffffff” bghovercolor=”#dd3333″ title_active_bg=”#81d742″ cnt_bg_color=”#ffffff”][vc_column_text]
Model / parameter | M1/125 |
Turbine…………………………………………. | Platypus 315 Stainless Steel |
Turbine rating…………………………………. | Refer performance graphs |
Runner…………………………………………. | Platypus impulse |
Jet circle diameter (mm)…………………… | 125 |
Minimum operating head (m)……………… | 10 |
Maximum operating head (m)…………….. | 100 |
Rpm – 10 to 60 meters head………………. | 1500 |
Rpm – 60 to 100 meters head…………….. | 3000 |
Minimum flow rate (l/sec)………………….. | 1 |
Maximum flow rate (l/sec)…………………. | 9.5 |
Turbine casing……………………………….. | Marine grade Aluminium -powder coated |
Standard nozzle type | Nylon conical x 1 |
Spare nozzles……………………………….. | 2 other sizes |
Nozzle diameter range (mm)……………… | 10 to 24 @ 2 mm intervals |
Inlet pipe connection……………………….. | 2 inch table D flange |
Generator……………………………………… | High efficiency induction |
4 pole 1500 rpm 10 to 60 m head | |
2 pole 3000 rpm 60 to 100 m head | |
Maximum Output……………………………. | 800 watt |
Voltage (nominal)……………………………. | 230 volt single phase |
Frequency (nominal)………………………… | 50 Hz |
Excitation capacitors……………………….. | 3 x 22mF for 1500 rpm |
(voltage rating 440 V)……………………….. | 3 x 16mF for 3000 rpm |
Generator to turbine coupling……………… | Direct |
System Control | |
Induction generator controller…………….. | IGC-10 |
(Electronic Governor) | |
Voltage………………………………………… | 230 volt single phase |
Voltage regulation (% of rated voltage)…. | +/- 2% |
Power rating (w)……………………………… | 1800 watts @ 230 volt |
Frequency…………………………………….. | 50 Hz |
Frequency regulation (%)………………….. | +/- 2% |
(for unity power factor loads)……………… | |
Output power wave form……………………. | Sinusoidal |
Dump load elements………………………… | Resistive solid core (stove element type) |
Number of elements………………………… | 1 of @ 1 kW |
AC outlet………………………………………. | 3 pin socket |
System monitoring | |
Operating water head……………………….. | 1000 kPa for 1500 rpm |
(60 mm gauge oil damped)………………… | 600 kPa for 3000 rpm |
Consumer load volts (Vac)………………… | Moving iron meter (90 Deg) |
Total generator current (Aac)……………… | Moving iron meter (90 Deg) |
System Protection | |
Overvoltage……………………………………. | Platypus overvoltage trip device |
Trip setting 310 V | |
Overcurrent……………………………………. | Miniture circuit breaker 4 amp |
Hydraulically limited | |
Dimensions and weights | |
Size (mm) L x D x H……………………….. | 340 x 500 x 520 |
Weight…………………………………………. | 45 kg |
Options | |
Discharge pit with base plate……………… | Polypropylene pit & galvanized steel base plate |
Dimensions…………………………………… | 565 L x 565 D x 320 H |