Battery Charging Units


Specifications


MODEL PM1000
Generator maximum output 750 W
TURBINE
Runner Platypus 316 Stainless Steel Impulse
Runner jet circle diameter (mm) 100
Minimum operating head(m) 5
Maximum operating head (m) 80
Minimum flow rate (l/sec) 0.5
Maximum flow rate (l/sec) 7.5
Turbine Casing Marine grade Aluminium-powder coated
Standard nozzle type Nylon conical x 1
Nozzle diameter range (mm) 10 to 24 @ 2 mm intervals
Inlet pipe connection

2 inch table D flange

   
GENERATOR
Alternator Permanent magnet brushless
Voltage 12, 24 & 48
Generator to turbine coupling Direct
SYSTEM CONTROL
Charge control regulator Electronic Constant Voltage Taper
Current B-SR50 or BX-SR50
Cubicle Steel enclosure IP55 (Powder coated)
Voltage (V) 13 - 70
Voltage regulation
(% of rated voltage) +/- 1%
Power rating (W) 360 at 12V
  750 at 24 & 48V
Dump load elements Resistive solid core (finned air cooled)
Number of elements 1 for 1 to 400 watts (B-SR50)
2 for 401 to 750 watts (BX-SR50)
SYSTEM MONITORING
Battery Charge Current Analogue 0 to 30 Amp at 12 & 24V
  Analogue 0 to 15 Amp at 48V
Dump Load Current Analogue 0 to 30 Amp at 12 & 24V

Analogue 0 to 15 Amp at 48V
Battery Voltage Analogue 0 to 15V at 12V
  Analogue 0 to 30V at 24V
  Analogue 40 to 60V at 48V
Battery Status Light emitting diode (LED)
Pressure gauge 800 kPa (oil damped)
SYSTEM PROTECTION
Overcurrent Circuit breaker



DIMENSIONS & WEIGHTS
Item PM1000 B-SR50 Governor
Size (mm) (LxDxH) 340x340x285 375x210x460
Weight (kg) 18 10.3
OPTIONS
Discharge pit with base plate Polypropylene pit & Galvanised steel
base plate
Dimensions (mm) 565 L x 565 D x 320 H
Filter
Electric solenoid valve
Hot water element for gravity fed system